User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-968M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386] 
10
1003 ABORT The system could not allocate a tone receiver for the 
test. The system may be oversized for the number of 
tone detectors present or some tone detectors may be 
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, 
refer to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, 
refer to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at one-minute 
intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a valid ISDN-PRI test call. 
Use the list isdn-testcall command to determine which 
call is using the port (from the M/T Port column). Either 
wait for the test call to complete (as indicated in the Start 
Time and Duration fields of the above display), or abort 
the test call with the clear isdn-testcall tg/mem 
command, where tg/mem is determined from the 
B-channel field of the above display.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort and the port is not in 
use, escalate the problem.
2000 ABORT Response to the test request was not received within the 
allowable time period.
2100 ABORT System resources required to run this test are not 
available.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-278. TEST #9 NPE Cross Talk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page










