User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-951M/T-ANL (Maintenance/Test Analog Port) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error code appears in the Error Log only if the MTB circuit pack has 
been removed since the Error Log was last cleared. Verify that the circuit 
pack has been reinserted.
b. This error indicates a hardware failure on the Analog Port circuitry. 
Replace the Maintenance/Test circuit pack if the alarm is not resolved by 
the command above.
c. This error indicates that call processing records did not agree with 
on-board records for the hook state (on-/off-hook) of the Maintenance/Test 
Analog Port. This error is not service-affecting and no action is required.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
M/T-ANL Error Log Entries
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off
 Board Test to Clear Value
0
1
 (a) 0 Any Any Any test port PCSSpp
1 (b) 41018 none MINOR ON test port PCSSpp l r 3
18  0 busyout port PCSSpp WARNING OFF release port PCSSpp
257  Any NPE Crosstalk test (#9) MINOR ON test port PCSSpp l r 3
513  Any Analog Port Sanity Test 
(#963)
MINOR ON test port PCSS01 r 2
769  Any Analog Port Digital 
Loop Around Test (#13)
MINOR ON test port PCSSpp r 3
3840(c) Any Hook State Inquiry test 
(#566)