User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-949M/T-ANL (Maintenance/Test Analog Port) 
10
M/T-ANL (Maintenance/Test Analog 
Port)
The Maintenance/Test Analog Port is port number 1 on the TN771 
Maintenance/Test circuit pack. This port is used by the Automatic Transmission 
Measurement System (ATMS) as an Originating Test Line (OTL) or Terminating 
Test Line (TTL) for test calls over analog trunks. Figure 10-71
 shows a typical 
ATMS configuration.
M/T-ANL maintenance ensures that the analog trunk’s testing function is 
operating correctly. An alarm against M/T-ANL can reduce service, but it will not 
block it. To accurately measure performance and health of analog trunks, the 
TN771 should be replaced when a new circuit pack is available.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the 
carrier where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
M/T-ANL Minor test port PCSSpp l  Maintenance/Test 
Analog Port
M/T-ANL Warning release port PCSSpp  Maintenance/Test 
Analog Port