User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-931MMI-BD 
10
Error Log Entries and Test to Clear Values
Notes:
a. The circuit pack stopped functioning or it was physically removed from the 
system. The alarm logs approximately 11 minutes after the circuit pack 
has been removed and/or the SAKI Sanity Test (#53) fails.
If the circuit pack is in the system and the red LED is on, follow the 
instructions for a red alarm in ‘‘
Control and Port Circuit Pack Status LEDs’’ 
in Chapter 7, ‘‘
LED Interpretation’’. Also, see “Handling Common Port 
Circuit Packs.”
b. This circuit pack has been busied out using the busyout board PCSS 
command.
c. There are more than four MMI circuit packs in the system. Remove the 
circuit pack that generated the error in the error log by locating the slot 
indicated by the error.
1. Run the short test sequence first. If all tests pass, run the long test sequence. Refer to the appropriate 
test description and follow the recommended procedures.
Table 10-264. MMI-BD Error Log Entries 
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test board PCSS sh r 1
1 (a) Any None MIN ON
18 (b) 0 Busyout board PCSS WNG OFF release board PCSS
217 (c) 0 None WNG ON
257 (d) 65535 Control Channel Loop Test 
(#52)
MIN ON test board PCSS r 3
513 (e) 4352 
to 
4357
Uplink error from pack
769 (f) Any MMI Synchronization 
Status Test (#1123)
None
1281 (g) Any Circuit Pack Restart Test 
(#594)
MAJ ON
1538 (h) Any Software detected error MIN ON
1793 (i) ANY TSI XTalk (#6) MIN ON test board PCSS l r 3
2049 (j) Any  TSI Loop (#1108) MAJ ON test board PCSS l r 3