Maintenance Object Repair Procedures 
Page 10-928MODEM-PT (Modem Pool Port) 
10
Table 10-263. TEST #99 Modem Pool Audit Test
Error 
Code
Test 
Result Description/ Recommendation
NONE ABORT The system was not able to allocate all the necessary 
resources to execute this test. An ABORT simply 
indicates that the conversion resource was in use when 
the audit was performed. No repair action is necessary 
unless it was known that the conversion resource was 
actually idle during the test (yellow in-use LED was off) 
or was busied out before the test was run. If this is the 
case, a TN758 failure condition may exist and the 
following procedure should be used:
1. Busyout both of the TN758 Pooled Modem 
conversion resources on the circuit pack containing 
the failing conversion resource.
2. If the test continues to abort, replace the Pooled 
Modem circuit pack and retest.
3. If the circuit pack fails after replacement, escalate 
the problem.