User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-927MODEM-PT (Modem Pool Port) 
10
Modem Pool Audit Test (#99)
This audit updates the Modem Pool conversion resource status contained in the 
TN758 Pooled Modem circuit pack’s microprocessor. It does not actually test the 
Pooled Modem circuit pack; therefore, there are no FAIL codes. The audit can 
only be performed on idle conversion resources. If the conversion resource is in 
use, the audit aborts.
5013 FAIL The Modem Pool Port did not respond with an on-hook 
message when the connection to the Data Channel was 
broken, indicating a likely problem with the TN758 
Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5014 ABORT The Network Control Channel allocated for this test did 
not respond correctly to the setup message sent to it 
after the connection was established.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit 
pack using the test data-module command (refer to 
the DATA-CHL maintenance strategy).
3. If the DATA-CHL circuit pack tests pass, escalate 
the problem.
5015 ABORT Data Channels 1 and/or 3 have not been administered.
1. Administer the Data Channels and retest.
Table 10-262. TEST #98 Modem Pool Conversion Resource Loop Around 
Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page