User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-920MODEM-PT (Modem Pool Port) 
10
1020 ABORT The test did not run due to a previously existing error on 
the specific port or because of a more general circuit 
pack error.
1. Examine the Hardware Error Log for existing errors 
against this port or the circuit pack, and attempt to 
diagnose the previously existing errors.
2000 ABORT The response to the test request was not received within 
the allowable time period.
2012 ABORT Internal System Error.
2100 ABORT System resources required for this test are not available.
2103 ABORT The system could not make the conference connection 
for the test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-261. TEST #97 Modem Pool Conference Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page