User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-902MET-LINE (MET Line) 
10
1004 ABORT The port was seized by a valid call during the test. The 
test has been aborted. Use the display port PCSSpp 
command to determine the station extension, attendant 
number, or trunk group/member number of the port. Use 
the status station, status attendant, or status trunk 
command to determine the service state of the port. If 
the service state indicates that the port is in use, then 
the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 8, ‘‘
Maintenance 
Commands and Trouble-Clearing Aids’’ for a full 
description of all possible states.) You must wait until the 
port is idle before retesting. Attendants are always in 
use (off-hook) if the handset is plugged in and the port is 
not busied out.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort and the port is not in 
use, escalate the problem.
2000 ABORT Response to the test request was not received within the 
allowable time period.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The test failed due to an internal system error.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-257. TEST #61 MET Line Station Audits Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page