Maintenance Object Repair Procedures 
Page 10-887MET-LINE (MET Line) 
10
1004 ABORT The port was seized by a valid call during the test. The 
test has been aborted. Use the display port PCSSpp 
command to determine the station extension of the port. 
Use the status station command to determine the 
service state of the port. If the service state indicates 
that the port is in use, then the port is unavailable for 
certain tests. (See Chapter 8, ‘‘
Maintenance Commands 
and Trouble-Clearing Aids’’, for a full description of all 
possible states.) You must wait until the port is idle 
before retesting.
NOTE:
The battery feed circuitry is tested for proper 
battery voltage by testing the switchhook state. In 
response to the test message, the on-board 
firmware terminates the line and checks for 
switch-hook presence. The termination is then 
removed, and a check is made for no switch-hook 
presence. The MET set must be on-hook for the 
test to execute.
1. If the port status is idle, then retry the command at 
1-minute intervals a maximum of 5 times.
2. If the test continues to abort and the port is not in 
use, escalate the problem.
1018 ABORT Test disabled via software patch.
1. Escalate to next tier level.
2000 ABORT This port may have been busied out by system 
technician.
1. Look in the Error Log for Error Type 18 (port busied 
out) for this port. If this error type is present, then 
release the port via the release station 
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
Table 10-253. TEST #35 Port Diagnostic Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page