Maintenance Object Repair Procedures 
Page 10-885MET-LINE (MET Line) 
10
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested 
for proper battery voltage by testing the switchhook state. In response to the test 
message, the on-board firmware terminates the line and checks for switch-hook 
presence. The termination is then removed, and a check is made for no 
switch-hook presence. The MET set must be on-hook for the test to execute.
0NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Check to ensure that the board translations are 
correct. Use the list config command, and resolve 
any problems that are found.
2. If the board was found to be correctly inserted in 
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should 
re-establish the linkage between the internal ID and 
the port. If this is not the case, check to ensure that 
there is a valid board inserted.