User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-878MET-LINE (MET Line) 
10
■ In Service—Once the system receives a message from the voice terminal 
communicating that it is present, the station is put into the in-service state. 
The terminal can also be forced into the in-service state if it goes off-hook 
while it is in the ready-for-service state.
When the status station command has been run, and the status screen 
appears, the status is reported as either out-of-service, in-service (as stated in 
the preceding list), or disconnect (the station is in the ready-for-service state).
Hardware Error Log Entries and Test to Clear 
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the 
set options command.
MET Line Error Log Entries
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None
18 (b) 0 busyout port 
PCSSpp
WARNING OFF release port PCSSpp
130 (c) None WARNING ON test port PCSSpp sh
257 (d) 40988 None MIN/WRN
2
OFF
513 (e) 40965 Hybrid Line Station 
Audits Test (#61)
WARNING OFF test port PCSSpp sh r 4
769 Port Diagnostic 
Test (#35)
MIN/WRN
2
ON test port PCSSpp l r 3
1025 Hybrid & Conf. 
Circuits Test (#57)
MIN/WRN
2
ON test port PCSSpp l r 3
1537 (f) 40968 None MIN/WRN
2
OFF
1793 TDMNPE Crosstalk 
Test (#6)
MIN/WRN
2
ON test port PCSSpp l r 3
2049(g) 32770
2049(h) 40967
3840(i) 40989