DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-778ISDN-LNK (ISDN-PRI Signaling Link Port) 
10
Table 10-218. TEST #643 Signaling Link Board Check 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 
times.
1700 ABORT Rollabout video abort. The PRI terminal adapter associated with 
this D-channel port is detached from the circuit pack. This is a 
normal abort when the rollabout video feature is enabled. To 
complete test on this port, either:
1. Re-attach the disconnected PRI terminal adapter and retry test 
command, or
2. Disable the rollabout video feature on this circuit pack by 
entering change ds1 PCSS and set the field "Alarm when PRI 
Endpoint Detached?" to "y."
8 FAIL The DS1 circuit pack is not in-service.
1. Check the Hardware Error Log for entries logged against 
DS1-BD and consult the DS1-BD (DS1 Interface Circuit Pack) 
Maintenance documentation for repair procedures.
PASS The DS1 Interface circuit pack transporting the ISDN-PRI Signaling 
Link Port is in-service.
Continued on next page