Maintenance Object Repair Procedures 
Page 10-766HYB-LINE (Hybrid Line) 
10
Table 10-214. TEST #62 Hybrid Line Ringer Update Test 
Error 
Code
Test 
Result Description/ Recommendation
3 ABORT This port may have been busied out by system 
technician.
1. Look in the Error Log for Error Type 18 (port busied 
out) for this port. If this Error Type is present, the 
release the port via the release station 
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not 
available. The port may be busy with a valid call. Use 
the display port PCSSpp command to determine the 
station extension number of the port. Use the status 
station command to determine the service state of the 
port. If the service state indicates that the port is in use, 
then the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 10, "Maintenance 
Commands and Trouble-Clearing Aids" for a full 
description of all possible states.) You must wait until the 
port is idle before retesting. Attendants are always in 
use (off-hook), if the handset is plugged in and the port 
is not busied out.
1. If the port status is idle, then retry the command at 
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
PASS Hybrid Station Ringer Update passed
1. If complaints still exist, investigate using other circuit 
pack tests on this circuit pack, and by examining the 
terminal, wiring, and connections.
Continued on next page