User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-760HYB-LINE (Hybrid Line) 
10
Table 10-212. TEST #60 Hybrid Line Lamp Updates Test 
Error 
Code
Test 
Result Description/ Recommendation
1 ABORT A request for a remote station lamp update aborted 
even though all internal resources were correctly 
allocated.
1. Look in the error log for error type 18 (port busied 
out) for this port. If this error type is present, release 
the port via the release port UUCSSpp command or 
the release station extension command, and then 
run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a 
maximum of 5 times.
4. If the test continues to abort, escalate the problem.
2 ABORT Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
3 ABORT The station is in a ready for service or an out of service 
state. This may be due to wiring or an unplugged or 
defective set.
1. Make sure terminal is connected and the wiring is 
correct.
2. Retry the command at 1-minute intervals a maximum 
of 5 times.
3. If the test continues to abort, escalate the problem.
Continued on next page