User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-758HYB-LINE (Hybrid Line) 
10
2000 ABORT Response to the test request was not received within the 
allowable time period.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1,2,3 FAIL No response was received within the allowable time 
period on one of the transmissions to the terminal. This 
indicates that something is wrong with the data link to 
the voice terminal. This could be a sleeping set problem 
or it may be due to wiring or an unplugged or defective 
set.
1. Check for errors in the error log, for example, error 
1537.
2. Remotely issue the busyout and release busy 
commands, and run the short test sequence on the 
port to check for other errors associated with the port 
or terminal.
3. Check the wiring to the set if it appears that the 
terminal is not responding to any tests; otherwise, 
replace the terminal and rerun the test.
4. If the test still fails, replace the circuit pack and 
reconnect the original terminal.
PASS Hybrid Line Remote Digital Loop Around Test passed. 
The hybrid circuit pack is sending and receiving proper 
messages to and from the voice terminal.
1. If problems still exist, investigate using other circuit 
pack tests and by examining the station, wiring, and 
connections.
Table 10-211. TEST #59 Hybrid Line Remote Digital 
Loop Around Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page