Page 10-746HYB-LINE (Hybrid Line) 
10
Hybrid Electronic Power Feed Test (#56)
In this test, the software requests that the EPF be turned on for a given port. An 
attempt is made to turn on the power unit from the station. If no current is being 
drawn, this probably indicates that the station is not connected. If an overcurrent 
condition is sensed (that is, too much current is being drawn), this may indicate a 
short in the loop or a defective voice terminal. Depending on what condition is 
sensed, a message is returned stating that either the EPF was turned on 
successfully with no problems or that an overcurrent condition is sensed. This 
test is repeated once more five seconds later. If either test is not successful, the 
test aborts (see first ABORT entry in the table below).
Table 10-208. TEST #56 Hybrid Electronic Power Feed Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not 
available. The port may be busy with a valid call. Use 
the display port PCSSpp command to determine the 
station extension number of the port. Use the status 
station command to determine the service state of the 
port. If the service state indicates that the port is in use, 
then the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 10, "Maintenance 
Commands and Trouble-Clearing Aids" for a full 
description of all possible states.) You must wait until the 
port is idle before retesting. Attendants are always in 
use (off-hook) if the handset is plugged in and the port is 
not busied out.
1. If the port status is idle, then retry the command at 
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.