User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-729FL-DATA (Flash Data Consistency) 
10
73 FAIL The update files, translations, and announcements are different in 
both SPEs. The Active SPE has the most current translations and 
announcements, and the Standby SPE has the most current update 
file.
74 FAIL The update files, translations, and announcements are different in 
both SPEs. The Active SPE has the most current announcements, 
and the Standby SPE has the most current update file and 
translations.
1. Issue the save translations command.
2. Issue the save announcements command.
3. Follow the procedures for Error Code 64.
76 FAIL The update files, load vintages, and announcements are different in 
both SPEs. The Active SPE has the most current announcements, 
and the Standby SPE has the most current update file.
77 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current 
translations and announcements, and the Standby SPE has the most 
current update file.
78 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current 
announcements, and the Standby SPE has the most current update 
file and translations.
1. Follow the procedures for Error Code 4 to get the correct load 
vintage. After running the test card-mem long command, check 
for Error Codes 32 or 64. Follow the recovery procedure under 
the applicable error code.
80 FAIL The update files and announcements are different in both SPEs. The 
Standby SPE has the most current update file and announcements.
1. Issue the save announcements command to save 
announcements on both SPEs.
2. Follow the procedures for Error Code 64.
Table 10-205. TEST #421 Flash Data Consistency Check Test — Continued
Error 
Code
Test 
Result Description/Recommendation
Continued on next page