Maintenance Object Repair Procedures 
Page 10-728FL-DATA (Flash Data Consistency) 
10
65 FAIL The update files and translations are different in both SPEs. The 
Standby SPE has the most current update file, and the Active SPE 
has the most current translations.
66 FAIL The update files and translations are different in both SPEs. The 
Standby SPE has the most current update file and translations.
1. Issue the save translations command to save translations on 
both SPEs.
2. Follow the procedures for Error Code 64.
68 FAIL The update files and load vintages are different in both SPEs. The 
Standby SPE has the most current update file.
69 FAIL The update files, load vintages, and translations are different in both 
SPEs. The Standby SPE has the most current update file, and the 
Active SPE has the most current translations.
70 FAIL The update files, load vintages, and translations are different in both 
SPEs. The Standby SPE has the most current update file and 
translations.
1. Follow the procedures for Error Code 4 to get the correct load 
vintage. After running the test card-mem long command, check 
for Error Codes 32 or 64. Follow the recovery procedure under 
the applicable error code.
72 FAIL The update files and announcements are different in both SPEs. The 
Standby SPE has the most current update file and the Active SPE has 
the most current announcements.
1. Issue the save announcements command to save 
announcements on both SPEs.
2. Follow the procedures for Error Code 64.
Table 10-205. TEST #421 Flash Data Consistency Check Test — Continued
Error 
Code
Test 
Result Description/Recommendation