Maintenance Object Repair Procedures 
Page 10-716EXT-DEV ADMIN? Y (External Device Alarm) 
10
2000 ABORT Response to the test request was not received within the 
allowable time period.
1. Retry the command at 1 minute intervals a maximum 
of 5 time.
2. (Maintenance Board) If the test continues to ABORT 
with error code 2000, check for system powering 
problems with the A carrier. Look for and resolve all 
AC-POWER and CARR-POW alarms in a multicarrier 
cabinet or DC-POWER alarms in a single carrier 
cabinet. Then, repeat the test.
3. (Maintenance Board) If the test continues to ABORT 
with a 2000 error code, check for and resolve all 
maintenance circuit pack errors. Then, repeat the 
test.
4. If the test continues to ABORT with a 2000 error 
code, then escalate the problem.
2029 
2100 
2319 
2320 
2500
ABORT Internal System Error
1. Retry the command at 1 minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-203. TEST #120 External Device Alarm Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page