Page 10-695EXP-INTF (Expansion Interface Circuit Pack) 
10
5002 FAIL Initialization failure: Expansion Interface circuit pack reset 
successfully and restarted execution. But the Expansion Interface 
circuit pack has determined that a lightwave transceiver was not 
attached to the backplane connector when the Expansion Interface 
circuit pack was last reset. If this system does not have duplicate 
Expansion Interface Links, all users in the EPN will be without 
service until this problem is resolved. If this system does have 
duplicate links, the backup Expansion Interface Link will be 
unavailable until this problem is resolved.
1. Attach lightwave transceiver to 25-pair backplane connector in 
slot belonging to Expansion Interface circuit pack.
2. Reset the circuit pack again.
3. If the reset fails with an error code other than 5002, refer to the 
appropriate Maintenance documentation.
4. If the reset fails again with Error Code 5002, replace the 
lightwave transceiver, reset the circuit pack, and execute the 
reset board PCSS command again.
5. If the reset fails again with Error Code 5002, the new lightwave 
transceiver may be defective, or the Expansion Interface circuit 
pack may need to be replaced.
5016 
5017 
5018 
5019 
5032 
5033 
5048 
5064 
5080 
5096 
5112
FAIL Initialization failure: Expansion Interface circuit pack reset 
successfully and restarted execution. But the Expansion Interface 
circuit pack detected communication errors during the self-test 
phase of the hardware initialization. The nature of the failure may 
prevent the Expansion Interface circuit pack from communicating 
with its neighbor Expansion Interface circuit pack on the opposite 
end of the fiber. The fault itself may be either on the Expansion 
Interface circuit pack or on the lightwave transceiver.
1. If all other tests on this Expansion Interface circuit pack are 
passing and no other errors have been logged against this 
circuit pack, replacement of the lightwave transceiver or the 
circuit pack are recommended, but not critical.
2. If all other tests on this Expansion Interface circuit pack are not 
passing or other errors have been logged against this circuit 
pack, the lightwave transceiver and/or the Expansion Interface 
circuit pack should be replaced.
Table 10-197. TEST #336 Expansion Interface Reset Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page