User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-686EXP-INTF (Expansion Interface Circuit Pack) 
10
2 FAIL The test tone was transmitted and detected correctly, but the 
correct data packet was not detected by the TN778 Packet Control 
circuit pack. This error only applies to the TN570 Expansion 
Interface circuit pack.
1. Test the TN778 Packet Control circuit pack to verify that it is 
functioning properly. If any tests fail, investigate those tests and 
repair the Packet Control circuit pack.
2. If the Packet Control circuit pack checks out OK, issue the test 
board PCSS long command on the Expansion Interface circuit 
pack.
3. If Test #242 continues to fail, replace the Expansion Interface 
circuit pack. Then, issue the test board PCSS long command 
on the new Expansion Interface circuit pack.
4. If Test #242 continues to fail, replace the lightwave transceiver, 
reset the circuit pack and issue the test board PCSS long 
command on the Expansion Interface circuit pack.
Table 10-195. TEST #242 Expansion Interface Lightwave 
Transceiver Loop Around Test — Continued
Error 
Code
Test 
Result Description/Recommendation
Continued on next page