Maintenance Object Repair Procedures 
Page 10-684EXP-INTF (Expansion Interface Circuit Pack) 
10
1031 ABORT If the Expansion Interface circuit pack is in an EPN and is active 
and is in slot A01 or B02, this test CANNOT be executed. If the 
lightwave transceiver loop around is activated, it is impossible to 
deactivate it.
1. If a Standby Expansion Interface circuit pack pair exists, make 
that pair active via the set expansion-link PCSS command, 
where PCSS is the address of a Standby Expansion Interface 
circuit pack.
2. If the Expansion Interface Link switch is successful, the 
lightwave transceiver Loop Around Test may now be executed 
on the original Expansion Interface circuit pack in the EPN.
1139 ABORT  The Packet Bus in an Expansion Port Network (Port Network 2 or 3) 
has a major alarm against it. This test needs to use the alarmed 
port network’s Packet Bus.
1. Resolve the Packet Bus alarm.
2. Retry the command.
1141 ABORT  The Packet Control circuit pack is out-of-service.
1. Determine if the Packet Control circuit pack is busied out by 
checking the Hardware Error Log to see if Error Type 18 has 
been logged against PKT-CTRL. If Error Type 18 is present, 
release the circuit pack via the release packet-control 
command, and retry the command.
2. If the Packet Control circuit pack is NOT busied out, refer to 
PKT-CTRL (Packet Control circuit pack) Maintenance 
documentation for the recommended repair procedure.
1144 ABORT  The Packet Bus in the Processor Port Network has a major alarm 
active against it. This abort code only appears when the test is run 
in an EPN.
1. Resolve the alarm in the PPN.
2. Retry the command.
Table 10-195. TEST #242 Expansion Interface Lightwave 
Transceiver Loop Around Test — Continued
Error 
Code
Test 
Result Description/Recommendation
Continued on next page