Page 10-664EXP-INTF (Expansion Interface Circuit Pack) 
10
d. This alarm is raised after an EI circuit pack has been removed from a slot 
for 11 minutes. The alarm is resolved when the EI circuit pack is inserted 
into this slot. Another way to resolve or prevent this alarm is to use the 
change circuit pack command to remove the EI circuit pack 
administrative entry for this slot after the EI circuit pack has been removed 
from the slot. Or, if the circuit pack is in the system and the red LED is on, 
then follow the instructions for "Red (alarm)" in the "Control and Port Circuit 
Pack Status LEDs" section in Chapter 7, "LED Interpretation".
e. Error Type 257 with Aux Data 85 through 88 indicates that this EI circuit 
pack is detecting incorrect data on the incoming fiber bit stream. The data 
is originating at the opposite EI circuit pack. These errors could result from 
a bad timing reference on the network which contains the EI circuit pack 
on the opposite end of the fiber. For example, if the error is logged against 
the 1B01 (PPN) EI circuit pack, then the bad timing reference is on the 
EPN. Resolve any EXP-INTF errors 2305, 769, or 770. Resolve any 
TONE-BD, TDM-CLK, or SYNC errors. Finally, if the errors continue to 
occur, perform the following procedure:
1. If the EI circuit pack reporting the error is part of the Active link and 
a Standby link exists, switch to the Standby link.
2. Reset the EI circuit pack at the opposite end of fiber.
3. Issue the test board PCSS repeat 10 command, where PCSS is 
the address of the EXP-INTF circuit pack reporting the error. If 
Tests #241 or #316 fail even once, follow the procedures 
associated with the failures.
4. Wait 15 minutes. Then check the Error Log to see if new errors of 
type 257 have been detected.
5. If errors are present, reset the EI circuit pack reporting the errors.
6. Wait five minutes. Then check the Error Log to see if new errors of 
type 257 have been detected.
7. If errors are present, replace the EI circuit pack or transceiver at the 
opposite end of the fiber.
8. Wait 15 minutes. Then check the Error Log to see if new errors of 
type 257 have been detected.
9. If errors are present or if this error occurs intermittently (over one 
week’s time), replace the EI circuit packs or transceivers on this 
link.
f. Error Type 513 with Aux Data 5 through 7 indicates an ON BOARD 
hardware failure of the circuit packs RAM or ROM. Replace the EI circuit 
pack or transceiver.
g. Error Type 1538 indicates a hyperactive EI circuit pack that is generating 
an abnormal amount of control messages to the Processor circuit pack. 
When this error was generated, the EI was automatically reset by the 
system. If this system does not have duplicate EI Links, service to the EPN 