Page 10-649ETR-PT (Enhanced Tone Receiver Port) 
10
2006 ABORT This abort code indicates that the active Tone-Clock 
circuit pack or a Tone Detector circuit pack may not be 
functioning properly. On G3r V2 systems, this abort can 
also be caused by a mismatch between the 
companding mode administered for the system and that 
of the Tone Detector circuit pack.
1. [G3r V2] Make sure that the companding mode of 
the system matches that of the Tone Detector: 
mu-law for TN748; A-law for TN420.
2. Test the 
active
 Tone-Clock circuit pack in the port 
network with the test tone-clock PC command and 
refer to the TONE-BD section for failures.
3. Retry the command at 1-minute intervals a maximum 
of five times.
4. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to 
run this test. 
1. Retry the command at 1-minute intervals a maximum 
of 5 times. 
2. If the test continues to abort, escalate the problem.
1-122 FAIL DTMF digits were not detected correctly. 
1. Run the short test sequence via the test port 
PCSSpp sh r 1 command.
2. If the problem persists, the system is still operating 
properly but capacity will be reduced. To restore 
performance to normal, replace the circuit pack 
containing the defective ETR-PT (Enhanced Tone 
Receiver Port). Follow the procedures described in 
the TONE-BD section for replacing a tone/clock 
circuit pack.
Table 10-187. TEST #42 Tone Detection Verification Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page