Maintenance Object Repair Procedures 
Page 10-623DUPINT (Duplication Interface Circuit Pack) 
10
FAIL The handshake to one of the Duplication Interface circuit packs has 
stopped. The circuit pack may be defective or communication to the circuit 
pack is hampered.
1. Look in the Hardware Error Log for error types against TAPE. If TAPE 
error types are present, resolve them since TAPE error types can 
cause Test #315 to fail. Refer to TAPE Maintenance documentation for 
recommended repair strategy.
2. After any TAPE error types are resolved, issue the test 
duplication-interface command on the suspect Duplication Interface 
circuit pack. If Test #315 fails on Duplication Interface A, Duplication 
Interface A is defective. Replace the Duplication Interface A circuit 
pack. If Test #315 fails on Duplication Interface B, Duplication 
Interface circuit pack A or Duplication Interface circuit pack B may be 
defective. In this case, it is necessary to determine which Duplication 
Interface circuit pack (A or B) is the defective one. To do this, issue the 
test duplication-interface A command. If Test #280 fails on 
Duplication Interface A, (and Test #315 has just failed on Duplication 
Interface B), Duplication Interface circuit pack A is defective and 
should be replaced. If Test #280 passes on Duplication Interface A 
(and Test #315 has just failed on Duplication Interface B), replace the 
Duplication Interface circuit pack B.
3. Reissue the test duplication-interface command on the Duplication 
Interface circuit pack that was replaced. If Test #315 still fails, check 
for problems with the Inter-Carrier Cables (ICCs). If any of the ICCs is 
defective, replace it.
4. Rerun the test.
NO 
BOARD
The Duplication Interface circuit pack has failed to handshake with either 
the active Maintenance/Tape Processor (in the case of Duplication 
Interface circuit pack A) or with Duplication Interface circuit pack A (in the 
case of Duplication Interface circuit pack B).
1. Follow the FAIL directions above.
PASS The tested Duplication Interface circuit pack is present and sane enough 
to handshake.
Table 10-179. TEST #315 Duplication Interface Circuit Pack 
Status Query Test — Continued
Error 
Code
Test 
Result Description/Recommendation
Continued on next page