Maintenance Object Repair Procedures 
Page 10-604DTMR-PT [Dual Tone Multifrequency Port (TTR)] 
10
Table 10-168. TEST #42 Tone Detection Verification Test 
Error 
Code
Test 
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources 
needed for this test or there was an Internal System 
Error.
1 ABORT The system could not allocate all the resources needed 
to test the DTMR port.
1001 ABORT The system was unable to put the DTMR port in the 
appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test 
connection. This could happen when the system is 
heavily loaded. If the system is not heavily loaded, then 
test the TDM Bus via the test tdm [a|b] command. Refer 
to the TDM-BUS (TDM Bus) Maintenance 
documentation for details.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a Tone Generator for the 
test connection. This could happen when the system is 
heavily loaded or there is not a Tone-Clock circuit pack 
in the port network when this test is being executed.
1. Make sure there is a Tone-Clock circuit pack in the 
same port network.
2. If a Tone-Clock circuit pack is missing, install one in 
the same port network.
3. Allow about one-minute for the Tone-Clock 
maintenance to run on the newly inserted 
Tone-Clock circuit pack.
4. Retry the command at one-minute intervals a 
maximum of five times.
5. If the test continues to abort, escalate the problem.
Continued on next page