User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-595DS1-BD (DS1 Interface Circuit Pack) 
10
The 
list measurements ds1 summary
 command will display the length of time the 
test ran (
Test Duration
 field) and number of bit errors detected (
Loopback/Span 
Test Bit-Error Count
 field).
To restore the trunks or ports on the TN767E DS1 Interface circuit pack to the 
in-service state, execute the release board command.
Table 10-166. TEST #1216 End Loopback/Span Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal system error
1. Retry the 
test ds1-loop PCSS end-loopback/span-test
 command at 
1-minute intervals a maximum of 5 times.
1005 ABORT End Loopback/Span Test cannot be executed in the current configuration. To 
run this, the TN767E or later suffix DS1 must be administered for 24-channel 
operation. The "Bit Rate" field on the DS1 circuit pack administration form must 
be set to "1.544" for 24-channel operation.
1015 ABORT Ports on the DS1 Interface circuit pack have not been busied out to 
out-of-service.
1. Enter the busyout board PCSS command to put all trunks or ports of the 
DS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page