User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-576DS1-BD (DS1 Interface Circuit Pack) 
10
1950 ABORT Another loopback/span test is already executing on the DS1 board or the board 
is in a network requested loopback mode (Line loopback or Payload loopback). 
The hardware error log will indicate whether a Customer Loopback Jack Test, 
Far CSU Loopback Test, or the One-Way Span Test is executing or if the board 
is in line loopback or payload loopback mode. Only one long-duration 
loopback/span test can be active at a given time. Thus, if a loopback/span test 
is already active, that test must be terminated via the test ds1-loop PCSS 
end-loopback/span-test command in order to execute this test.
1951 ABORT The CSU Equipment Loopback Test could not be executed because the 120A 
CSU Module was not physically installed. Physically connect the 120A CSU 
Module to the TN767E board on the back of the port carrier.
ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test was not received within the allowable time period. This 
may be due to hyperactivity. Error type 1538 in the error log indicates 
hyperactivity. The hyperactive circuit pack is out of service and one or more of 
the following symptoms may be exhibited.
1. The DS1-BD tests (such as test 138 and test 139) are aborting with error 
code 2000.
2. The tests run on the ports of this circuit pack are returning a no board result.
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are 
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system, 
and all of the trunks for this circuit pack are placed into the out of service 
state. The system will try to restore the circuit pack within 15 minutes. 
When no faults are detected for 15 minutes, the DS1 interface circuit 
pack is restored to normal operation. All of the trunks for the DS1 
interface circuit pack are then returned to the in service state. 
Hyperactivity is often caused by the associated facility. In such a case, 
faults (such as slips, misframes, or blue alarms) would be entered in the 
error log. In addition, many hardware errors would be logged against the 
associated trunk circuits. If the facility is OK and the error occurs again 
after 15 minutes, replace the circuit pack.
Table 10-160. TEST #1210 CSU Equipment Loopback Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page