Maintenance Object Repair Procedures 
Page 10-541DS1-BD (DS1 Interface Circuit Pack) 
10
SAKI Sanity Test (#53)
This test is destructive. This test resets the circuit pack.
0 NO BOARD The test could not relate the internal ID to the port (no board). 
This could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the add 
ds1 PCSS command to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine if the board is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the 
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 10-148. TEST #53 SAKI Sanity Test 
Error 
Code Test Result Description/ Recommendation
None ABORT System resources required for this test are not available. 
1. Retry the command at 1-minute intervals a maximum of 5 times.
1005 ABORT Wrong circuit pack configuration to run this test. This error applies only to 
DS1 Interface circuit packs. It means the DS1 Interface circuit pack is 
providing timing for the system and, therefore, it cannot be reset without 
major system disruptions.
1. If the circuit pack needs to be reset, then set synchronization to another 
DS1 Interface circuit pack or to the Tone-Clock circuit pack and try 
again. Refer to "SYNC (Synchronization)".
Continued on next page
Table 10-147. TEST #52 Control Channel Looparound Test  — Continued
Error 
Code Test Result Description/ Recommendation
Continued on next page