Maintenance Object Repair Procedures 
Page 10-518DIOD-TRK (DIOD Trunk) [G1.2SE] 
10
For example, you may also clear errors generated from other tests in the testing 
sequence.
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
NPE Crosstalk Test (#6) X ND
Dial Tone Test (#0) X ND
Loop Around and Conference Test (#33) X ND
Audit Update Test (#36) X X ND
Table 10-140. TEST #0 Dial Tone Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Could not allocate system resources to run this test.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not 
available. The port may be busy with a valid call. Use 
the command display port PCSSpp to determine the 
trunk group/member number of the port. Use the status 
trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, 
then the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 10, "Maintenance 
Commands and Trouble-Clearing Aids" for a full 
description of all possible states.) You must wait until the 
port is idle before retesting.
1. If the port status is idle, then retry the command at 
one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Continued on next page