Maintenance Object Repair Procedures 
Page 10-516DIOD-TRK (DIOD Trunk) [G1.2SE] 
10
c. Aux data 57376 - No loop current on incoming call
Aux data 57424 - No loop current on outgoing call
These errors cause the Dial Tone Test (#0) to run and are only considered 
a problem if the Dial Tone Test fails (in which case Error Type 1537 also 
shows up). In this case, the trunk may be put in "Ready-for-Service" state 
(shown as "disconnected" by status command), which allows only 
incoming calls. Run the Dial Tone Test (#0) and follow its outlined 
procedures.
d. Single polarity ringing current - This error results from abnormal ringing 
current, but does not prevent the incoming call from being accepted. This 
error code is only logged as an informational event and causes no other 
testing to occur.
e. Late CO Trunk release - This error indicates that the CO releases the trunk 
at least four minutes after the PBX dropped the call. This error code is only 
logged as an informational event and causes no other testing to occur.
Table 10-139. DIOD Trunk Errors with NO Tests 
Error
Type
Aux 
Data Description and System Action System Technician Action
769 57392 CO not releasing after call is dropped 
from PBX end (TN747B), or the loop is 
not open after a disconnect (TN765). 
After several occurrences, an off-board 
(TN747B) or on-board (TN465) warning 
alarm is generated.
Refer problem to CO.
2561 57345 Single polarity ringing current. This error 
results from abnormal ringing current, 
but does not prevent the incoming call 
from being accepted. One cause could 
be that the reverse current detector 
associated with the port is failing. (Will 
not be detected by any tests.) The other 
cause could be that normal current is 
not detected. In this case, neither 
incoming nor outgoing calls can be 
completed, and the dial tone test also 
fails.
Check for other errors.
Continued on next page