User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Routine Maintenance Procedures 
Page 5-50System Features 
5
13. Check all wirings to verify good connections between the two test ports.
14. Place a call from one voice terminal to another voice terminal using the Tie 
Trunk ports assigned. Dial TAC and extension. For example, if TAC of Tie 
Trunk group is 110 and station number is 5012, then dial 110 5012. If the 
call cannot be made, either one of these ports could be defective. There 
are four ports on TN760B (port 1, 2, 3, and 4), try different combinations to 
determine defective ports.
15. If there is a defective port on the circuit pack, try to switch to an unused 
port. However, if all ports are normally used, then replace the circuit pack.
16. Disconnect the jumpers between two ports. Then use administration 
terminal and trunk printouts to restore all trunk group changes to normal 
values.
Table 5-4. Carrier Lead Appearances at 
110 Cross-Connect Field
110 Connecting 
Block Terminals CO Trunk TN747B Tie Trunk TN760B
1T1T1
2R1R1
3T11
4R11
5E1
6M1
7T2T2
8R2R2
9T12
10 R12
11 E2
12 M2
13 T3 T3
14 R3 R3
15 T13
16 R13
17 E3
18 M3
Continued on next page