User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-500DIOD-DS1 (DS1 DIOD Trunk) 
10
Notes:
a. Error Type 1—Aux Data 57408
—No tip ground is detected on an 
outgoing call.
Aux Data 57476
—Rotary Dial before Wink.
Aux Data 57477—Rotary Dial pulse too early.
Aux Data 57485—Wink too short for a valid signal.
Aux Data 57487
—PBX could not get ‘‘loop close’’ signal.
The DS1 Interface circuit pack detected a hardware fault. These errors will 
cause the Dial Tone Test (#314) to run and are only considered a problem 
if the Dial Tone Test fails (in which case Error Type 1025 will also show 
up). In this case, the trunk may be put in the ready-for-service state 
(shown as ‘‘disconnected’’ by the status command), which allows only 
incoming calls. Run the Dial Tone Test (#314) and follow the procedures.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field 
set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of 
service, then the alarm will be upgraded to a MAJOR alarm.
3. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options 
command.
1281 Conference Circuit 
Test (#7)
MIN/
WRN
3
ON test trunk <grp>/<mbr> 
l r 4
1537 NPE Crosstalk Test 
(#6)
MIN/
WRN
3
ON test trunk <grp>/<mbr> 
l r 3
1793(i) test board PCSS l
2049(j) 57473 
57474 
57475
2305(k) 50944
2562(l) 16665
2817(m) 52992
3840(n) Port Audit and 
Update Test (#36)
DS1 DIOD Trunk Error Log Entries — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
Continued on next page