User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-497DIG-LINE (Digital Line) 
10
6 ABORT This port may have been busied out by system 
technician.
1. Look in the Error Log for Error Type 18 (port busied 
out) for this port. If this error type is present, the 
release the port via the release station
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum 
of 5 times.
4. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not 
available.
1392 ABORT This port is currently a TTI port and the test will not 
execute on it.
1. Verify that the port is a TTI port using either the 
display port command (the display shows that the 
port is a TTI port) or the list config command (the 
display shows a t for the port).
2. If either list config or display port indicate that the 
port is 
not
 a TTI port, escalate the problem. If both 
commands indicate that the port is a TTI port, the 
abort is correct, and no action is necessary.
2000 ABORT Response to the test request was not received within the 
allowable time period.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to fail, escalate the problem.
PASS Station Audits passed. This Digital Port circuit pack is 
functioning properly.
1. If complaints persist, investigate by using other port 
tests, and by examining the station, wiring, and 
connections.
Table 10-134. TEST #17 Station (Digital) Audits Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page