Maintenance Object Repair Procedures 
Page 10-494DIG-LINE (Digital Line) 
10
1000 ABORT System resources required to run this test are not 
available. The port may be busy with a valid call. Use 
display port UUCSSpp/PCSSpp to determine the 
station extension or attendant number of the port. Use 
status station or status attendant to determine the 
service state of the port. If the service state indicates 
that the port is in use, then the port is unavailable for 
certain tests. (See Chapter 10, "Maintenance 
Commands and Trouble-Clearing Aids", for a full 
description of all possible states.) You must wait until the 
port is idle before retesting. Attendants are always in 
use (off-hook) if the handset is plugged in and the port is 
not busied out.
1. If the port status is idle, then retry the command at 
1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1392 ABORT This port is currently a TTI port and the test will not 
execute on it.
1. Verify that the port is a TTI port using either the 
display port command (the display shows that the 
port is a TTI port) or the list config command (the 
display shows a t for the port).
2. If either list config or display port indicates that the 
port is 
not
 a TTI port, escalate the problem. If both 
commands indicate that the port is a TTI port, the 
abort is correct, and no action is necessary.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-133. TEST #16 DIG-LINE Station Lamp Updates Test — Continued
Error 
Code
Test 
Result Description/ Recommendation