Maintenance Object Repair Procedures 
Page 10-493DIG-LINE (Digital Line) 
10
Table 10-133. TEST #16 DIG-LINE Station Lamp Updates Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
1 ABORT This port may have been busied out by system 
technician.
1. Look in the Error Log for Error Type 18 (port busied 
out) for this port. If this error type is present, then 
release the port via the release station 
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum 
of 5 times.
4. If the test continues to abort, escalate the problem.
3 ABORT Station may be in ready-for-service or out-of-service 
state.
1. Use status station command to verify state of 
station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum 
of 5 times.
4. If the test continues to abort, escalate the problem.
Continued on next page