Maintenance Object Repair Procedures 
Page 10-487DIG-LINE (Digital Line) 
10
EFP and PPF is that, if the port goes into a overcurrent state, PPF does not report 
this change of state because it is a transient state which will not last more than 
50ms. If the over current persists the power will be shut off automatically and an 
EPF_off_overcurrent message is sent uplink.
Table 10-131. TEST #11 Digital Line Electronic Power Feed Test
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not 
available. The port may be busy with a valid call. Use 
display port UUCSSpp/PCSSpp to determine the station 
extension or attendant number of the port. Use status 
station or status attendant to determine the service 
state of the port. If the service state indicates that the 
port is in use, then the port is unavailable for certain 
tests. (See Chapter 10, "Maintenance Commands and 
Trouble-Clearing Aids", for a full description of all 
possible states.) You must wait until the port is idle 
before retesting. Attendants are always in use (off-hook) 
if the handset is plugged in and the port is not busied 
out.
1. If the port status is idle, then retry the command at 
1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page