User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-485DIG-LINE (Digital Line) 
10
1003 ABORT The system could not allocate a tone receiver for the 
test. The system may be oversized for the number of 
Tone Detectors present or some Tone Detectors may be 
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, 
refer to TTR (TTR Level) Maintenance 
documentation.
2. Look for TONE-PT errors in the Error Log. If present, 
refer to TONE-PT (Tone Generator) Maintenance 
documentation.
3. If neither condition exists, retry the command at 
1-minute intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The 
test has been aborted. Use display port UUCSSpp to 
determine the station extension or attendant number of 
the port. Use status station or status attendant to 
determine the service state of the port. If the service 
state indicates that the port is in use, then the port is 
unavailable for certain tests. (See Chapter 10, 
"Maintenance Commands and Trouble-Clearing Aids", 
for a full description of all possible states.) You must wait 
until the port is idle before retesting. Attendants are 
always in use (off-hook) if the handset is plugged in and 
the port is not busied out.
1020 ABORT Test disabled via background testing. Use status 
station command to determine when station is available 
for testing.
2000 ABORT Response to the test request was not received within the 
allowable time period.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-130. TEST #9 Digital Line NPE Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page