Page 10-481DIG-LINE (Digital Line) 
10
14 FAIL The primary channel (voice, Information Channel 1 or I1) 
is not operating properly. User impact may range from 
noticing nothing to not being able to use the port. Check 
the results of "Voice and Control Channel Local Loop 
Test (#13). If that test fails, suspect the Digital Line 
circuit pack. If that test passes then replace the terminal. 
If both test fail, and component replacement does not 
change the results, then:
1. Run circuit pack tests to check the tone generator 
circuit pack and the Tone Detector circuit pack 
using the test board UUCSS s command.
2. Resolve any problems that are detected on the Tone 
Generator circuit pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit pack 
are functioning properly, and the tests still fail, 
escalate the problem. (
(Continued)
Table 10-129. TEST #1201 Digital Terminal Remote 
Loop Around Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page