User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-480DIG-LINE (Digital Line) 
10
1004 ABORT The port was seized by a valid call during the test. The 
test has been aborted. Use the display portUUCSSpp 
command to determine the station extension or 
attendant number of the port. Use status station or 
status attendant to determine the service state of the 
port. If the service state indicates that the port is in use, 
then the port is unavailable for certain test. (See Chapter 
10, "Maintenance Commands and Trouble-Clearing 
Aids", for a full description of all possible states.) You 
must wait until the port is idle before resetting. 
Attendants are always in use (off-hook) if the handset is 
plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort and the port is not in 
use, escalate the problem.
1005 ABORT The installed circuit pack does not support this 
operation.
2000 ABORT Response to the test request was not received within the 
allowable time period.
1. Retry the command at 1-minute intervals a maximum 
of 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT System resources required to run this test are not 
available.
1. Make sure terminal is connected and repeat test.
2. If the test continues to abort, escalate the problem.
3. If test fails replace terminal and repeat test.
4. Retry the command at 1-minute intervals a maximum 
of 5 times.
Table 10-129. TEST #1201 Digital Terminal Remote 
Loop Around Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page