User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-479DIG-LINE (Digital Line) 
10
1002 ABORT The system could not allocate time slots for the test. The 
system may be under heavy traffic conditions or it may 
have time slots out-of-service due to TDM-BUS errors. 
Refer to TDM-BUS (TDM-Bus) Maintenance to diagnose 
any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not 
handling heavy traffic, repeat test at 1-minute 
intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the 
test. The system may be oversized for the number of 
Tone Detectors present or some Tone Detectors may be 
out of service.
1. Look for TTR-LEV errors in the Error Log. If present 
refer to TTR-LEV (TTR-Level) Maintenance 
documentation.
2. Look for TONE-PT errors in the Error Log. If present, 
refer to TONE-PT (Tone Generator) Maintenance 
documentation.
3. If neither condition exist, retry the command at 
1-minute intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
Table 10-129. TEST #1201 Digital Terminal Remote 
Loop Around Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page