User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-476DIG-LINE (Digital Line) 
10
30 seconds and then plug it back in. If the voice terminal still does not 
operate, then check for a short in the wiring, a damaged jack, an incorrect 
type of voice terminal, or a defective voice terminal.
Once the problem has been resolved, it may take up to 1 hour for the 
alarm to clear due to ‘‘leaky bucket’’ strategy. If the problem cannot be 
resolved by one of the steps above, then replace the circuit pack.
h. An in-line maintenance error has generated an off-board warning due to 
some problem with the link to the voice terminal. This can be ignored if no 
user complaints are received. Otherwise, make sure the voice terminal is 
connected, check for defective wiring, check for a defective voice 
terminal, and move voice terminal to a jack that is closer to the switch (in 
terms of feet of wiring between the jack and the switch). If the problem still 
exists, replace the circuit pack. Once the problem has been resolved, the 
alarm will be retired after a predetermined amount of time.
i. This indicates that the station went off-hook while it was in the 
ready-for-service state. Use the status station command to determine the 
state of the station. The off-hook should have moved the station to 
ready-for-service. No craft action is necessary.
j. This is the code that is generated when the link between the circuit pack 
and the voice terminal is successfully reset. No craft action is necessary.
k. No terminal is connected to the Digital Line board. No maintenance action 
is required.
l. An uplink message has been logged indicating that the Electric Power 
Feed (EPF) is on with no load on it. No action is necessary.
m. The circuit pack’s message buffer is full. This may be caused by having 
many display phones with heavy traffic connected to the circuit pack. No 
action is necessary.
n. Internal system error. No action is necessary.
o. There is a problem with the voice terminal EEPROM. When the voice 
terminal is repaired the alarm will be resolved with the passing of time.