Maintenance Object Repair Procedures 
Page 10-462DID-TRK (DID Trunk) 
10
Port Audit Update Test (#36)
This test sends updates of the DID port translation for all ports on the circuit pack 
that have been translated. The update is non-disruptive and guards against 
possible corruption of translation data contained on the circuit pack. No 
response message is expected from the circuit pack once it receives translation 
updates. The port translation data includes: wink or immediate start trunk, dial 
tone or rotary dialing trunk, rotary dialing inter-digit timing, Network balance 
R/RC, and disconnect timing.
PASS Current flow was detected for this port.
1. User-reported troubles on this port should be 
investigated using other port tests and by examining 
connections.
2. Refer problem to the CO.
0NO 
BOARD
The test could not relate the internal ID to the port (no 
board).
1. Check to ensure that the board translations are 
correct. Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should 
re-establish the linkage between the internal ID and 
the port.
Table 10-126. TEST #35 Port Diagnostic Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page