Table 10-122. TEST #7 Conference Circuit Test 
Error
Code
Test 
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this 
test.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test were not available. The 
port may be busy with a valid call. Use the display port 
UUCSSpp command to determine the trunk group/member 
number of the port. Use the status trunk command to determine 
the service state of the port. If the service state indicates that the 
port is in use, then the port is unavailable for certain tests. You 
must wait until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), 
check the error log for error type 1025 (see the Error Log 
table for a description of this error and required actions). The 
port may be locked up.
2. If the port status is idle, retry the command at 1 minute 
intervals for a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system 
may be under heavy traffic conditions, or it may have time slots 
out of service due to TDM-BUS errors. Refer to the TDM-BUS 
(TDM bus) Maintenance documentation to diagnose any active 
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling 
heavy traffic and the port status is idle, retry the command at 
1 minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.