User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-435DID-DS1 (DS1 DID Trunk) 
10
Conference Circuit Test (#7)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The 
NPE controls port connectivity and gain, and provides conferencing functions on 
a per-port basis. The Conference Circuit Test verifies that the NPE channel for 
the port being tested can correctly perform the conferencing function. The NPE is 
instructed to listen to several different tones and conference the tones together. 
The resulting signal is then measured by a Tone Detector port. If the level of the 
tone is within a certain range, the test passed.
0NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Check to ensure that the board translations are 
correct. Use the lIst config command and resolve 
any problems that are found.
2. If the board was found to be correctly inserted in 
step 1, issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should 
re-establish the linkage between the internal ID and 
the port. If this is not the case, check to see that 
there is a valid board inserted.
Table 10-121. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page










