Maintenance Object Repair Procedures 
Page 10-434DID-DS1 (DS1 DID Trunk) 
10
2053 ABORT At least one of the following errors is found on the DS1 
circuit pack: 1281—Loss of signal, 1793—Blue Alarm, 
2049—Red Alarm, 2305—Yellow Alarm, 1537—
Hyperactivity.
Look for the above error types in the Hardware Error Log 
and follow the procedures given in the appropriate 
DS1-BD or UDS1-BD maintenance documentation for 
the listed error types.
ANY FAIL The test failed. This can be due to on-board or off-board 
problems. Off-board problems of concern include 
EXP-PN and EXP-INTF faults, TDM-BUS faults, and 
faults associated with the tone detectors/tone 
generators. Clear all off-board problems before 
replacing the board. Keep in mind that a TDM-BUS 
problem is usually the result of a faulty board connected 
to the backplane or bent pins on the backplane.
1. Look for EXP-PN and/or EXP-INTF errors in the error 
log. If present, refer to the EXP-PN and the EXP-INTF 
Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, 
refer to the TDM-BUS Maintenance documentation.
3. Look for TONE-BD and/or TONE-PT errors in the 
error log. If present, refer to the TONE-BD and the 
TONE-PT Maintenance documentation.
4. Retest when the faults from steps 1, 2, and 3 are 
cleared. Replace the board only if the test fails.
PASS The port is correctly using its allocated time slots. 
User-reported troubles on this port should be 
investigated using other port tests and by examining 
station, trunk, or external wiring.
Table 10-121. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page