User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-433DID-DS1 (DS1 DID Trunk) 
10
1003 ABORT The system could not allocate a tone receiver for the 
test. The system may be oversized for the number of 
Tone Detectors present or some Tone Detectors may be 
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, 
refer to TTR-LEV (TTR Level) Maintenance 
documentation.
2. Look for TONE-PT errors in the Error Log. If present, 
refer to TONE-PT (Tone Generator) Maintenance 
documentation.
3. If neither condition exists, retry the test at one-minute 
intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a user for a valid call. Use the 
display port UUCSSpp command to determine the 
trunk group/member number of the port. Use the status 
trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, 
then the port is unavailable for certain tests. You must 
wait until the port is idle before retesting.
1. If the port status is idle, retry the command at 1 
minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1020 ABORT The test did not run due to a previously existing error on 
the specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this 
port or the circuit pack and attempt to diagnose the 
previously existing error.
2000 ABORT Response to the test request was not received within the 
allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-121. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page