User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-408DATA-CHL (Network Control Data Channel) 
10
Table 10-112. TEST #111 Data Channel Local Loop Back Test 
Error 
Code
Test 
Result Description/Recommendation
4 ABORT For this test, an Error Code of 4 can have one of two different meanings:
a. The target DATA-CHL is busy and, therefore, not available for use.
b. Internal system error
Determine if the target DATA-CHL is in use for some other function (that is, 
CDR Link, System Printer Link, Journal Printer Link, PMS Link, or secondary 
administration terminal connection) as described previously in the "Status 
of network Control Data Channels" section. If so, check for errors on the 
function that is using the DATA-CHL. If there are no errors, there is a high 
probability that the DATA-CHL is not defective. Proceed with the remaining 
steps only if it is necessary to completely test the target DATA-CHL.
1. If the target DATA-CHL is in use for some other function, busyout the 
function (PRI-CDR/SEC-CDR, SYS-PRNT, PMS-PRNT/JNL-PRNT, 
PMS-LINK) or the DATA-CHL (secondary administration terminal 
connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Restore any busied out PRI-CDR/SEC-CDR, SYS-PRNT, 
PMS-PRNT/JNL-PRNT, PMS-LINK MOs to service before moving on to 
another activity.
40
70
75
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page