Routine Maintenance Procedures 
Page 5-38System Features 
5
■ Analog Tie Trunk Back-to-Back Testing
■ Terminating Trunk Transmission Testing
■ Troubleshooting ISDN-PRI Problems
■ Troubleshooting PRI Endpoint Problems
■ Troubleshooting ISDN-PRI Test Calls
Complete descriptions of each feature are provided in the 
DEFINITY Enterprise 
Communications Server Release 5.4 Administration and Feature Description
. 
Refer to 
DEFINITY Communications System Generic 1 and Generic 3 — Console 
Operations
, 555-230-700, and 
DEFINITY Communications System Generic 1 and 
Generic 3 Voice Terminal Operations
 as required for detailed operating 
procedures (does not include Facility Test Calls, Analog Tie Trunk Back-to-Back 
Testing, Terminating Trunk Transmission Testing, Troubleshooting ISDN-PRI 
Problems, Troubleshooting ISDN-PRI Test Calls, or Troubleshooting ISDN-BRI 
Problems described in this chapter.)
Automatic Circuit Assurance
Requires the use of a display-equipped voice terminal (may be nondisplay type if 
the Voice Message Retrieval feature is provided) or an attendant console. An 
"ACA activate/deactivate" button (one per system) is required on the voice 
terminal or attendant console.
Automatic Circuit Assurance (ACA) assists users in identifying possible trunk 
malfunctions. The system maintains a record of the performance of individual 
trunks relative to short and long holding time calls. The system automatically 
initiates a referral call to an attendant console or display-equipped voice terminal 
when a possible failure is detected.
Holding time is the elapsed time from when a trunk is accessed to the time a 
trunk is released. When ACA is enabled via administration, the system measures 
the holding time of each call.
A short holding time limit and a long holding time limit are preset by the System 
Manager for each trunk group. The short holding time limit can be from 0 to 160 
seconds. The long holding time limit can be from 0 to 10 hours. The measured 
holding time for each call is compared to the preset limits for the trunk group 
being used.
Measurements are not made on personal CO lines, out-of-service trunks, or 
trunks undergoing maintenance testing.