Maintenance Object Repair Procedures 
Page 10-376CUST-ALM (Customer-Provided Alarming Device) 
10
Table 10-102. TEST #115 Customer-Provided Alarming Device Test 
Error 
Code
Test 
Result Description/Recommendation
(blank) 
1000 
2029
ABORT Internal system error
1. Try the command at 1-minute intervals a maximum of 5 times.
PASS The switch software successfully sent the request to the 
Maintenance/Tape Processor or EPN Maintenance circuit pack to turn on 
the CPAD. The CPAD must be physically inspected to verify that it is 
working. If the CPAD is working and the customer has complained that the 
CPAD did not indicate a system alarm when it occurred, then check the 
administered levels for turning on the CPAD via the Display 
System-Parameter Maintenance screen form. Compare these levels with 
the customer’s specifications. If Test #115 passes, and the CPAD is not 
being activated, check the connection of the CPAD to the 
Maintenance/Tape Processor or EPN Maintenance circuit pack. If the 
CPAD can be activated but cannot be deactivated, first check to make 
sure Emergency Transfer is not activated in the affected port network via 
the status system command. Emergency Transfer can be forced to 
manual OFF by the Emergency Transfer switch on the Maintenance/Tape 
Processor or EPN Maintenance circuit pack. If Emergency Transfer is OFF 
and the CPAD still cannot be deactivated, check the administered levels 
for the CPAD via the Display System-Parameter Maintenance screen form 
and compare against the alarm levels currently present in the system 
(display alarms command).
Continued on next page